top of page

Brand: SHANGFANG

Model: SF-808

 

Features 
Temperature Control
Manual/automatic defrost
Time,temp.setting to end defrost
Automaticlly defrost
Value Storing/Self Testing
Parameter Locking
 
Technical Data 
Range of temperature display:-45~100℃
Range of set temperature:-45~45℃
Accuracy:±1℃
Compressor: N.O. 10A/240VAC
Defrost: N.O. 10A/240VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm 

Parameters 

Parameter
Function
Set range
Default
E1
Lower setpoint limit
-45℃~Set temp.
-35℃
E2
Higher setpoint limit
Set temp.~45℃
20℃
E3
Temp.Hysteresis
1~10℃
4℃
E4
Comp.start delay time
0~10Min
2Min
E5
Offset on room temp.
-20~20℃
0
F1
Max.Defrost duration
1~60Min
20Min
F2
Defrost interval time
0~24Hr
6Hr
C2
High temperature alarm
C3~40℃
40℃
C3
Low temperature alarm
-40℃~C2
-40℃
C4
Alarm delay time
0~90Min
90Min

SF-808 TEMPERATURE CONTROLLER

SKU: R026046
$103.00Price
Quantity

    Haiton International Pty Ltd / Haiton Air Con & Refrigeration Pty Ltd

    LIDCOMBE (FLAGSTORE)

    Unit 19, 27, 31

    4A Bachell Avenue

    Lidcombe NSW 2141

    -

    (02) 9749 9532 / 9749 5401

    0425 470 512 / 0420 326 188

    -

    MON - FRI: 8am - 5pm

    SAT: 9am - 2pm

    KINGSGROVE BRANCH

    108/2 The Crescent, 
    Kingsgrove NSW 2208 

    -

    (02) 8384 9715

    0452 351 833

    -

    MON - FRI: 8am - 4:30pm
    SAT: Closed

    SMITHFIELD BRANCH

    5/189 McCredie Rd, 
    Smithfield NSW 2164 

    -

    (02) 8773 4301

    0420 326 188

    -

    MON - FRI: 8am - 4.45pm

    SAT: Closed

    Direct air conditioning importer, we provide parts and air conditioner installation for reverse cycle air conditioner, split system air conditioning, reverse cycle air con, ducted air conditioner. Best prices in Fujitsu split system, Panasonic aircon, Mitsubishi electric split system

    © 2024 ® 2011 Haiton International Pty Ltd. All rights reserved.

    bottom of page