Brand: SHANGFANG
Model: SF-212
Features
Temperature control
Light control
manual/automatic defrost by turning off
Time/temp. seting to end defrost
Re-start delay
Relay output :1HP(compressor)
Technical Data
Range of temperature displayded:-45℃~45℃
Range of set temperature: -45℃~45℃
Accuracy:±1℃
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
Compressor: N.O. 20A/250VAC(one HP)
Light: N.O. 5A/250VAC
Relay output:1HP(compressor)
Parameters
Parameter | Function | Set range | Default |
E1 | Lower setpoint limit | -45℃~Set temp. | -35℃ |
E2 | Higher setpoint limit | Set temp.~45℃ | 20℃ |
E3 | Temp.hysteresis | 1~10℃ | 4℃ |
E4 | Comp.start delay time | 0~10Min | 2Min |
E5 | Offset on room temp. | -5~5℃ | 0℃ |
E6 | Offset on room temp. | -5~5℃ | 0℃ |
F1 | Max.defrost duration | 1~60Min | 20Min |
F2 | Defrost interval time | 0~24Hr | 6Hr |
F3 | Defrost termination temp. | 0~20℃ | 8℃ |
F4 | Display during defrost | 0=Nomal display | 0 |