Brand: SHANGFANG

Model: SF-213

 

Features 
Temperature control
Light control
Electric heater defog
manual/automatic defrost by turning off
Time/temp. seting to end defrost
Celsiuc/Fahrenheit degress
Re-start delay
Relay output :1HP(compressor) 

Technical Data 
Range of temperature displayde:-45℃~45℃
Range of set temperature: -45℃~45℃ 
Accuracy:±1℃ (±2℉)
Compressor: N.O. 20A/250VAC
Defog: N.O. 10A/250VAC
Light: N.O. 5A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm 

Parameters
 

Parameter

Function

Set range

Default

E1

Lower setpoint limit

-45℃/-40℉~Set temp.

-35℃/-31℉

E2

Higher setpoint limit

Set temp.~45℃/120℉

20℃/68℉

E3

Temp.Hysteresis

1~10℃/1~18℉

4℃/7℉

E4

Comp.start delay time

0~10Min

2Min

E5

Offset on room temp.

-5~5℃/℉

0

E6

Offset on evap.Temp.

-5~5℃/℉

0

F1

Max.Defrost duration

1~60Min

20Min

F2

Defrost interval time

0~24Hr

6Hr

F3

Defrost termination temp.

0~20℃/32~68℉

8℃/46℉

F4

Display during defrost

0=Normal display
1=Last value before defrost

0

C1

Temperature unit

0=℃ 1=℉

0

 

 

SF-213 TEMPERATURE CONTROLLER

SKU: R026027
$238.00Price

    Address:​

    Unit 19/4A (Main Store) and Unit 27/4A

    Bachell Ave,

    Lidcombe  NSW 2141

    Call us 

    Tel: (02) 9749  5401
                   9749 9532

    Email us :

              info@haiton.com.au
              sales@haiton.com.au
              jeff@haiton.com.au
              lisa@haiton.com.au

     

    We Accept

    Trading Hour

              Mon - Fri 7:30 am -6:15 pm

              Sat 9:30 am -2:30 pm

     

    © 2023 by Copyright® 2011 Haiton International Pty Ltd, All rights reserved.