Brand: SHANGFANG

Model: ED-106

 

Features 
Temperature control
Evaporator fan control
Automatic/manual defrost
Defrost by electric heater
Time/temp. seting to end defrost
Re-start delay
Celsius/Fahrenheit degrees 

Technical Data 
Range of temperature display:45150  (45~150)
Range of set temperature:4545  (40~113)
Accuracy:±1(±2)
Compressor: N.O. 16A/250VAC
Defrost: N.O. 10A/250VAC
Evap. Fan: N.O. 5A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
 

 

Parameter List

 

Code
Function
Set range
Default
E1
Lower setpoint limit
-45°C/-45°F~Set temp.
-35°C/-31°F
E2
Higher setopint limit
Set temp.~45°C/113°F
45°C/113°F
E3
Temp.hysteresis
1~20.0°C / 1.8~36.0°F
4.0°C/7.2°F
E4
Comp.start delay time
0~10Min
2Min
E5
Offset on room temp.
-20.0~20.0°C / -36.0~36.0°F
0
E6
Offset on evap.temp.
-20.0~20.0°C / -36.0~36.0°F
0
C1
Temperature unit
0=°C 1=°F
0
F0
Defrost function
0=Electric heater 1=Hot gas
0
F1
Max.defrost duration
1~60Min
20Min
F2
Defrost interval time
0~24Hr
6Hr
F3
Defrost terimination temp.
0~30°C / 32~86°F
8°C/46
F4
Display during defrost
0=Nomal display 1=Last value before defrost
0
F5
Fan operationg fuction
0=Parallel with comp. 1=Continuous running except defrost
0
F6
Dripping time
0~30Min
2
F7
Fan operating fuction after defrost end
0=Temperature 1=Time
1
F8
Fan start-up delay after defrost end
0~10Min
2
F9
Fan start temperature after defrosting(evaporator)
-30~30°C / -22~86°F
5°C/41°F